Architectural Systems » Facade Systems » BG - 50 Curtain Wall System

Architectural Systems » Facade Systems » BG - 50 Curtain Wall System

 BG 50 - CHARACTERISTIC FEATURES

  • High performance curtain wall system.
  • Profil Genişliği: 50 mm
  • Profile Wall Thicknesses: 1,6 mm - 2,8 mm
  • Mullion Depths: 50, 80, 100, 120, 140, 160, 180, 200, 220mm
  • Transom Depths: 55, 85, 105, 125, 145, 165, 185, 205, 225mm
  • Maximum Glass Thickness: 42 mm
  • Insulation Bars: 14 mm – 30 mm
  • Thermal Insulation Value(Uf): 1,47 W/m²K
  • Application Alternatives: Capped, Fourside, Twoside, Structural Cells.
  • Opening Vent Alternatives: Top Hung, Parallel.

CATALOG & TEST REPORTS

TEST TYPE
 RESULTS (Accredited)
Air Permeability
Class 4 (600 Pa) EN 12207
Watertightness
Class RE1500 (1500 Pa) EN 12154
Resistance to the Wind Load
900 Pa (With 80mm transom pr.) EN 13116
Heat Transmission Coefficient
Uf: 1,47 - 3,85 W/m²K EN 10077-2
Acoustic Performance
Rw (C ; Ctr) = 32,6 (-1,6; -3,8) dB EN 10140-2 , EN 717-1
* For further information, please ask for the test reports.

Product User Projects